Monday, May 13, 2019

Process control Essay Example | Topics and Well Written Essays - 2500 words

Process control - Essay ExampleThis electric current is normally expressed by plotting the valve motivity on the (y-axis) a winst the play percentage under constant pressure derivative instrument on the (X-axis). There are two main types of the inherent liquify characteristics these are linear and passable percentage. A control valve is said to be linear if its inherent flow characteristics can be correspond on a graph by a straight line. The flow is usually directly proportionate to the valve choke. It is a straight line when represented on a rectangular coordinate of flow stride F or % F or Cv or % Cv versus or against the percentage extend at the optimum condition of constant drop in valve pressure (DPv). It can be deduced that an reach gain in travel consider or opening position, m, results in an equal increase in flow F (or Cv) at constant valve pressure drop (DPv). If m represents travel and F represents the rate of flow, then, dm= k dF where K is a proportional c onstant. Therefore the valve gain or sensitivity is self-governing of flow rate and valve opening. Shown by Kv = Df/dm = constant The valve gain (Kv) is the slope or burn of the rectangular coordinate or plot drawn. The slope of the graph remains constant and independent of the flow rate. A control valve is said to be equal percentage if equal increase in valve travel or opening m (or Z) produces or results in equal percentage increase in flow F. If the situation emerges at the optimum condition of constant drop in valve pressure (DPv), the valve is said to be inherently equal percentage. The valve gain is not constant in this case besides increase with an increase in flow rate. Therefore, when the control valve is just beginning to open at low flow rate, the valve gain is quite low and the change in flow is quite insensitive. At high flow during the pep pill portion of the travel, the valve gain is high which translates to rapid flow or sensitively for the same increase in valv e travel. When plotting the flow rate against valve travel or position, the slope is flat near the initial travel position, but the slope increases drastically with the flow as the valve opens on the upper section of the travel. It can be shown by a straight line plotted on a semi-logarithmic paper for log F against m. The fast open control valve characteristic is flattened in shape as opposed to the contoured valve plug. The flow of this valve increases apace up to the highest flow level with the least initial opening of the valve. In the lower section of travel position, the valve gain is so high for application and utilization in modulating control. The slope is then flat where the flow rate hardly increases with valve openings. Therefore, the Quick open control valve is restricted to a service of ON and collide with and in a specified application that needs discharge of flow. Applications of Control Valves Linear plugs are largely used on the dodgings where the valve pressu re drop in a major section of the total system pressure drop , where the valve is the major pressure loss mechanism. Linear control valves are used in about 10-15 % of all applications. Linear control valves are also used in gas process. In the gas process, there is a large volume, decreasing DP with an increasing load DP at maximum load. The maximum load DP is greater than 20% of minimum load DP. It is also apply in the gas compressor recycle control valve. Also, the linear valves are

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.